The Brace
The Column
The Patent
Load Tables
Installation
Images
Contact us


  Load Tables
 
PT BRACE – LATERAL BRACING
WIND REGIONS B, C & D
LABORATORY TESTED – ENGINEER CERTIFIED


350mm PT BRACE FRAME

HEIGHT
WIDTH
DEPTH
ULTIMATE LIMIT STATE LOAD
2370
350
62
6.5kN
2480
350
62
6.1kN
2670
350
62
5.7kN

450mm PT BRACE FRAME

HEIGHT
WIDTH
DEPTH
ULTIMATE LIMIT STATE LOAD
2370
450
62
11.3kN
2480
450
62
10.6kN
2670
450
62
10.0kN
2970
450
62
9.0kN

600mm PT BRACE FRAME

HEIGHT
WIDTH
DEPTH
ULTIMATE LIMIT STATE LOAD
2370
600
62
16.9kN
2480
600
62
15.9kN
2670
600
62
15.0kN
2970
600
62
13.5kN
3270
600
62
11.2kN
3570
600
62
10.2kN

NOTE: When PT Brace Frames are used in a stacked formation the value is limited to that of one PT Brace Frame, as the combined unit is governed by the hold downs at the lower level.

 

 

 

 

 

 

 
 